INSTALLATION
WALL DRILLING AND BRACKET FIXING
A
(2)
B
B
(OPTIONAL)
C
As a first step, proceed with the following drawings:
 A vertical line up to the ceiling or up to the upper limit, at the center of the area in which the
hood is to be fitted.
 A horizontal line A at 1320 – 1700 mm above the cooker top.
 A horizontal line B at a minimum 926 (868 optional) mm above the cooker top.
 A horizontal line C at a minimum 656 mm above the cooker top.
Mark Points:
 Mark a point (1) on the horizontal line A, 60 mm to the right of the vertical reference line.
 Repeat this operation on the other side, checking that the two marks are leveled.
 Mark a point (2) on the horizontal line B, 80 (135 optional) mm to the right of the vertical
reference line.
 Repeat this operation on the other side and on the vertical reference line, checking that the
60
(1)
60
80
80
135
135
(3)
80
80
12