1 - PRESENTATION
The WOOD-BURNING furnace H-03/70-C has a
decorative cast iron front and a sheet boiler, with
a maximum power of 22 kW (12,4 kW power
transferred to the water and 9,6 Kw transferred to
the environment). Supplied fully assembled from
the factory.
2 - INSTALLATION
IMPORTANT! All the local regulations, including
those that refer to national or European standards
must be complied with when installing the device.
If this device is used simultaneously in the same
room with other heating devices that need air for
combustion, it is advisable to provide an additional
input of outside air to facilitate combustion.
The operation of one or more heating devices in
the same room will reduce oxygen levels, making
the combustion of the furnace more difficult and
reduce the chimney flue.
The safety and performance of the furnace will
largely depend on how it is installed.
It is, therefore, imperative you install it correctly.
A safe installation of the furnace and chimney may
be bothersome at times, so it is advisable to ask an
expert to do this for you.
It is advisable to line the panels in the hood with
an insulating material (wool type or similar) to
prevent overheating.
2.1. SKETCH FOR THE BRICKWORK
• VERSION "A": CONVECTION with an exterior air
intake (clean air).
• VERSION "B" CONVECTION with air intake from
the actual room (recirculation of the same air)
VERSION "B"
IMPORTANT! The ventilation grid must be placed
in such a way that it does not interfere with its
movement.
The air coming out of the upper ventilation grid
can reach high temperatures; therefore, ensure
materials that cannot withstand the heat are not
used for the grids. They must be metallic. Do not
use wooden or plastic grids.
Do not place objects near the upper ventilation
grids. The hot air that comes out may ruin them.
The minimum recommended measurements of
the grids be 400 cm² to permit the free passage of
air. There is one at the bottom and another on the
top of the lining, as shown in the picture.
VERSION "A"