Step 10: Plug In the Washer and Dryer
Refer to sections on Electrical Requirements and
connect the washer and dryer to an electrical power
source.
WASHER
Plug cord into separately fused 15 Amp circuit.
Figure 19
ELECTRIC DRYER
Connect to 30 Amp circuit.
Figure 20
GAS DRYER
Plug cord into separately fused 15 Amp circuit.
Figure 21
801504
D254I
D254I
D275I
D254I
D254I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 11: Check Installation
Refer to Installer Checklist on the back cover and
make sure that unit is installed correctly.
Moving Unit to a New Location
Disconnect unit from electrical supply.
To prevent damage while moving the unit, the
shipping materials MUST BE reinstalled.
Reinstallation of Shipping Materials
Remove front access panel by removing two screws.
Place the shock sleeves on all four shock absorbers.
Refer to Figure 22.
Insert hooked end of shipping brace into the open slot
of the motor mount. Attach with bolts and lockwashers.
Refer to Figure 22.
Reinstall front access panel.
4
3
1
Shock Sleeves
2
Motor Mount
3
Bolts and Lockwashers
4
Hooked End of Shipping Brace
Figure 22
Refer to step 8 for proper procedures whenever the
unit is moved.
Installation
1
2
H336I
17