Step 6: Connect Dryer Exhaust System - Alliance Laundry Systems SWD441C Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation

Step 6: Connect Dryer Exhaust System

For further assistance, refer to sections on Location
Requirements and Dryer Exhaust Requirements.
WARNING
A clothes dryer produces combustible lint.
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.
DO NOT use plastic or thin foil ducting.
G
Locate unit so exhaust duct is as short as
G
possible.
Be certain old ducts are cleaned before installing
G
your new dryer.
Use 4 in. (10.2 cm) diameter rigid or flexible
G
metal duct.
The male end of each section of duct must point
G
away from the dryer.
Use as few elbows as possible.
G
Use duct tape or pop-rivets on all duct joints.
G
Ductwork that runs through unheated areas must
G
be insulated to help reduce condensation and lint
build-up on pipe walls.
Failure to exhaust dryer properly will void
G
warranty.
14
W116
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DO
Figure 14
NOTE: Venting materials are not supplied with the
unit (obtain locally).
SWD449N
DON'T
SWD449N
801504