Qlima PGU 2013 Instrucciones De Uso página 38

Ocultar thumbs Ver también para PGU 2013:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
DIAGRAMMATICAL REPRESENTATIONS OF OUTDOOR AREAS
Both ends open
SPECIFICATIONS
Max.Wattage:
Min. Wattage:
Gas Consumption:
Height:
4
38
WARNING: In the event of gas leakage, the appliance shall not be used or if
alight, the gas supply shall be shut off and the appliance shall be investiga-
ted and rectified before it is used again.
3. Turn the gas supply ON. And check all the connections with the soapy
water solution. No bubbles may appear!
4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply ON and recheck. Contact your dealer or gas supplier for
assistance if bubbles continue to appear.
Open side must be >25%
of total wall area
Model
Gas type
Countries of des-
BE-ES-FR-GB-GR-
tination (*)
IT-PT-LUX
Gas Category
I3+
Pressure (mBar)
28-30/37
(*) This appliance is not suitable for Germany, Austria, Swiss
Open
13,5 kW
5 kW
450 g/hr-982 g/hr
224 cm including stand
PGU2013
propane, butane or LPG only
NL-NO
I3 B/P
28-30
>30% of Total wall area
to be open and unrestricted
DK-FIN-SE
I3 B/P
30