Product specification
Indoor Unit
Outdoor Unit
Model
Power/Current
Power/Current
(For testing)
Refrigerant
Cooling Capacity
Cooling Capacity
(For testing)
JIS C 9612
[<70 dB(A)]
Noise Level
Conditions 1m
Distance Max. cooling
Air Circulation
Product Weight
Dimensions (H × W × D)
• Standby power consumption ≤ 0,9 W (when switched OFF by remote control, except under self-
protection control).
1. Standard piping length: 7,6 m.
2. Air filters are attached.
26
ACXF55-21800_FC1806-00_PS .indb 26
CS-PS9VKV-2
CU-PS9VKV-2
COOL
Single, 220 - 230V,
60Hz
650
[W]
3,00
[A]
910
[W](MAX)
4,30
[A](MAX)
R410A
[g]
710
2550
[W]
3200
[W](MAX)
[dB(A)]
10,5
[m
/min.]
3
9,0
[kg]
24,5
289×918×194
[mm]
542×780×289
CS-PS12VKV-2
CU-PS12VKV-2
COOL
Single, 220 - 230V,
60Hz
930
4,10
1200
5,00
R410A
880
3520
4200
40
42
47
47
11,0
9,0
28
289×918×194
542×780×289
2019/4/24 10:07:47