REPLACING LED AERATOR WITH 1.2 GPM AERATOR (INCLUDED)
1. Hold the end of the faucet spout
in one hand and grasp the LED
aerator firmly with your fingers.
Turn the LED aerator clockwise
and remove it from the faucet.

CARE AND MAINTENANCE

Clean periodically with a soft cloth. Avoid abrasive cleaners, steel wool, and harsh chemicals as these will dull the finish and void your
warranty.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
Leaks underneath
Bonnet has come loose or O-ring on
handle.
cartridge is dirty
or twisted.
Water does not
Rubber valve seat is dirty, stuck, or
completely shut off.
broken.
Faucet leaks around
Aerator incorrectly fitted.
aerator.
Improper water pattern.
Aerator dirty or small parts inside
aerator improperly installed.
www.homewerksww.com
1
CORRECTIVE ACTION
1. Move the handle to the OFF position. Unscrew the handle screw and remove the handle.
2. Tighten the bonnet by turning it clockwise. Move the cartridge stem to the on position. The leak should
stop draining out from around the cartridge stem.
3. Shut off the water supply. Remove the bonnet by turning it counterclockwise. Lift out the cartridge valve.
Inspect the larger O-ring on the cartridge bonnet and the smaller O-ring on the cartridge stem. Remove any
debris from the O-rings. If either O-ring is twisted, straighten it out. If either O-ring is damaged, replace
the cartridge by calling customer service.
4. Position the cartridge back into the faucet body. Make sure the ridges on the two sides of the cartridge
bonnet fit into the grooves on the two sides of the faucet body. Tightly screw the bonnet onto the faucet
body.
5. Re-install the handle.
1. Shut off the water supply to the faucet that leaks.
2. Remove the handle on the problem side. Loosen the bonnet by turning it counterclockwise. Lift out the
cartridge assembly.
3. Inspect the rubber valve seat in the faucet body. If there is debris or brass scrap on the surface of the
seat, remove it. If the rubber seat is stuck tightly in the water inlet hole, push it gently with a fingertip so that
it moves up and down smoothly. The spring (smaller end up) must be replaced underneath the valve
seat. If the rubber valve seat is worn out or broken, replace the cartridge by calling customer service.
4. Replace the cartridge in the faucet body. Make sure that the ridges on the two sides of the cartridge
bonnet fit into the grooves on the two sides of the faucet body. Tightly screw the bonnet onto the faucet
body.
5. Re-install the handle.
1. Unscrew the aerator by turning it clockwise. Inspect the black rubber packing inside the aerator. The
rubber packing should be flat.
2. Screw the aerator onto the spout end and tighten.
1. Remove the aerator from the spout end by turning it clockwise.
2. Gently flush the small parts inside the aerator to clear away any debris.
3. Re-install the small parts as shown in the exploded diagram. Metal screens must be flat and plastic
supporter must be straight.
4. Screw the aerator onto the spout end and tighten.
2. By hand, twist the 1.2 GPM
aerator (C) counterclockwise
into place. Do not overtighten.