Troubleshooting must be conducted by trained and experienced technicians!
Fault symptoms and troubleshooting methods:
Fault symptom
Cause
The power supply is abnormal
The AC contactor of the pump motor main
circuit does not pull in.
The motor does not
rotate when the Up
button is pressed
The circuit of limit switch is faulty.
The button switch is faulty.
The motor rotates reversely.
The platform ascends with light load, but can
not ascend with heavy load.
The motor rotates but
the platform does not
The hydraulic oil is insufficient or the grade is
rise when the Up button
incorrect
is pressed.
The manual oil drain plug of the solenoid valve
is not tightened.
The solenoid valve connector is blown.
The safety jaw is not separated from the
safety gear.
The safety jaw is not uplifted.
The lift does not descend
when the Down button is
The pneumatic solenoid valve does not work.
pressed.
The lowering solenoid valve does not work.
The explosion-proof valve is blocked
60
AE5301S/AE5301-3S
中文
EN
DE
Troubleshooting method
Perform inspection and troubleshooting, and connect the
electric wires.
The motor will run if the contactor is pressed with an
insulating rod forcibly. Inspect the control circuit, and
replace the contactor if the voltage at the contactor coil
terminal is normal.
If the failure disappears after short circuit connection
of the terminal SQ1 or SQ2 of the limit switch with wires,
inspect the limit switch and wire, and adjust or replace the
limit switch.
Inspect the button contracts and wires and eliminate the
fault.
Exchange the phase sequence of the incoming power lines.
Increase the safe pressure setting of the relief valve by
rightward rotating the valve slightly.
If there is dirt in the valve core of the lowering solenoid
valve, clean the valve core.
Refill or change the hydraulic oil.
Tighten the oil drain plug of the main lift or sub lift.
Replace the solenoid valve connector of the main lift or the
sub lift.
Extend the delay time of the time relay slightly.
The air pressure is insufficient, the safety jaw gets
stuck or the air pipe is broken. Adjust the pressure of
the air compressor, inspect the air pipe and perform
troubleshooting.
If the pneumatic circuit is blocked for the energized
pneumatic solenoid valve does not work, inspect or replace
the pneumatic solenoid valve.
Inspect the connector and coil of the lowering solenoid
valve and inspect weather the copper nut on the end of
solenoid is rightward tightened.
Remove the "explosion-proof valve" from the oil inlet
port at the bottom of main lift or sub lift hydraulic cylinders,
and clean the holes.