Multiple Port Shower Sump
Security
The shower sump may not be used for other liquid than water/bilge water.
Always install the pump with black lead (-) and brown lead (+).
Always use the fuse required, see "Design features" below.
The wire connections must be sealed with a marine sealant.
All electrical wiring must be clamped with the connections well above the bilge water level. Do not
remove the insulation more than necessary. All wiring connections should be sealed with a marine
sealant to avoid oxidation.
Do not run dry.
Type designation
Multiple Port Shower Sump - Part No 32-7650-01
Design features
Container:
Lid:
Capacity,
straight:
Capacity,
1 m (3 ft) head:
Check valve
Voltage:
Amperage:
Fuse size:
Intake hose:
Discharge hose:
Max dia:
Max höjd:
Vikt:

Mounting instructions

Fasten the shower sump to the hull by screws in the four mounting holes.
Operation
See illustration page 15.
A.
When the bilge water rises the magnet float (1), floats up and the air in the float house (2) is forced
out through the vent hole (3).
B.
The magnet float starts the pump (4) when bilge water reaches 50 mm. The valve (5) closes and
the magnet float stays in the start position due to vacuum inside the float house.
C.
When the bilge water has sunk to level 20 mm, air is let in through the air opening (6) in the float
house. The magnet float falls down and cuts off the power.
Original instructions
Thermoplastic, white
Acrylic, clear
61 l/min (13.6 V)
53 l/min (13.6 V)
Flapper valve, nitrile
12 V DC
3.2 A
4 A
1x3/4"
1x3/4" eller 1x1"
1x1
/8" eller 1x1
/2"
1
1
3/4"
290x210 mm
200 mm
1.2 kg