Notices of installation

9.1 Unpacking inspection

• Open the box and check air conditioner in area with good ventilation (open the door and window)
and without ignition source.
C
Note: Operators are required to wear anti-static devices.
• It is necessary to check by professional whether there is refrigerant leakage before opening the
box of outdoor machine; stop installing the air conditioner if leakage is found.
• The fire prevention equipment and anti-static precautions shall be prepared well before checking.
Then check the refrigerant pipeline to see if there is any collision traces, and whether the outlook
is good.

9.2 Safety principles for installing air conditioner

• Fire prevention device shall be prepared before installation.
• Keep installing site ventilated.(open the door and window)
• Ignition source,smoking and calling is not allowed to exist in area where R32 refrigerant located.
• Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and
gloves.
• Keep leak detector in working state during the installation.
• If R32 refrigerant leakage occurs during the installation, you shall immediately detect the
concentration in indoor environment until it reaches a safe level. If refrigerant leakage affects the
performance of the air conditioner, please immediately stop the operation, and the air conditioner
must be vacuumed firstly and be returned to the maintenance station for processing.
• Keep electric appliance, power switch, plug, socket, high temperature heat source and high static
away from the area underneath sidelines of the indoor unit.
• The air conditioner shall be installed in an accessible location to installation and maintenance,
without obstacles that may block air inlets or outlets of indoor/outdoor units, and shall keep away
from heat source, inflammable or explosive conditions.
• When installing or repairing the air conditioner and the connecting line is not long enough, the
entire connecting line shall be replaced with the connecting line of the original specification;
extension is not allowed.
• Use new connection pipe, unless re-flaring the pipe.

9.3 Requirements for installation position

• Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases.
Free match split type air conditioner / User Manual
27 / 172 EN