Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
Apply foam pad (E) to bottom of wall bracket (A).
1
Place wall bracket (A) on wall, resting on top of
display, and mark the center of mounting hole. Drill
a 1/4" (6mm) dia. hole to a minimum depth of 2".
Insert alligator anchor (D) into hole. Secure wall
bracket (A) to wall with security wood screw (C).
solid concrete
D
A
E
C
display
INCORRECT
concrete
wall
plate
plaster/
dry wall
WARNING
cinder block
CORRECT
concrete
wall
plate
plaster/
dry wall
• Tighten screws so that wall plate is fi rmly
attached, but do not overtighten. Overtightening
can damage screws, greatly reducing their
holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors
directly to load-bearing concrete.
• Never attach concrete expansion anchors
to concrete covered with plaster, drywall, or
other fi nishing material. If mounting to concrete
surfaces covered with a fi nishing surface is
unavoidable, the fi nishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker
than 5/8" (16 mm), custom fasteners must be
supplied by installer.
1
Drill holes and insert anchors (D).
2
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
5 of 20