Preparing the appliance before use
• If the accessories are too long, you can
cut one of them in order to adapt the
assembly to the thickness of the wall,
Fig. 15.
Fig. 16
• This accessory can be fitted to the wall
with screws and wall plugs or silicon,
plaster, etc.
EIf do not wish or need to use the air-
conditioning, remove the hose from the
hole and close the covers on the
accessory to close the hole in the wall.
Separating the flexible hose from
the indoor unit
The hose must be dismantled from the
indoor unit in order to fit it through the wall
(this is only possible on models with
disconnectable hose). To do this, proceed
as follows:
• Disconnect the appliance from the mains
Fig. 14
electricity supply.
• Remove the valve covert F, Fig.1, from
the indoor unit. The flexible hose join is
now visible, Fig. 18.
• To extract the electrical connection,
remove the screw and the cover, Fig.
19A which conceals it. Press the tabs on
the side of the connector carefully and
remove it from its housing, Fig. 19B.
A
Fig. 15
Fig. 17
• Dismantle the condensed water drainage
tube by turning it a 1/4 turn anti-
clockwise and remove it, Fig. 20. Be
particularly careful when removing this
tube as some of the water it contains
may splash.
59
Fig. 18
B
Fig. 19