WIRE FEEDER WELDER (180 MODEL)
TECHNICAL SPECIFICATIONS 180 Amp units (K2481-1, K2515-1, K2659-1, K2698-1)
INPUT – SINGLE PHASE ONLY
Standard Voltage/Frequency
230 V / 60 Hz
208 V / 60 Hz
RATED OUTPUT
Voltage/Duty Cycle
230 V 30%
208 V 30%
Welding Current Range
30-180 Amps
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage / Frequence
230/208 V
60 Hz
PHYSICAL DIMENSIONS
Height
Width
13.7 in.
10.15 in.
347 mm
258 mm
1
If connected to a circuit protected by fuses use Time Delay Fuse marked "D".
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and under-
stood the WIRE FEEDER WELDER
Operating Manual should install and oper-
ate this equipment.
• Machine must be plugged into a receptacle which is
grounded per any national, local or other applicable
electrical codes.
• The WIRE FEEDER WELDER power switch is to be in the
OFF ("O") position when installing work cable and gun
and when connecting power cord to input power.
-----------------------------------------------------------------
Input Current
20 Amps @ rated output
20 Amps @ rated output
Voltage at Rated Amperes
Current
130 Amps
20
17.6
130 Amps
OUTPUT
Maximum-Open Circuit Voltage
34 V
Fuse or Breaker Size
1
Input Amps
40 Amp Super Lag
Depth
Weight
18.2 in.
56 lbs.
462 mm
25.4 kg.
WARNING
Wire Speed Range
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Minimum Input Cable
20
14 AWG
SELECT SUITABLE LOCATION
Locate the welder in a dry location where there is free circulation
of clean air into the louvers in the back and out the front of the
unit. A location that minimizes the amount of smoke and dirt
drawn into the rear louvers reduces the chance of dirt accumula-
tion that can block air passages and cause overheating.
STACKING
WIRE FEEDER WELDER(180 MODEL) cannot be stacked.
TILTING
Each machine must be placed on a secure, level surface, directly
or on recommended cart. The machine may topple over if this
procedure is not followed.
A 1
INSTALLATION