SPECIFICATIONS
SOCKET TYPE
½" Female Square Drive
DISPLAY
• DISPLAY TYPE: Dot Matrix LCD (192 x 65
Resolution)
• VIEWING DIRECTION: 6:00
• BACKLIGHT: WHITE (LED)
SEALED BUTTON PAD
POWER - ON/OFF and torque re-zero
ENTER - measurement mode select and
menu entry
UP – increments settings and menu navigation
DOWN - decrements settings and menu
navigation
UNITS - units select (ft-lbs, in-lbs, Nm)
R
RECALL – Recalls last applied peak torque
FUNCTIONS
• Track - real time display of torque
• Peak Hold - 5 sec. flashing of peak torque on
release of torque
• First Peak - 5 sec. flashing of peak torque after
initial drop off in torque
• Peak Torque Recall - 5 sec. flashing display last
peak torque measurement
ACCURACY
• Temperature: 22°C (72°F)
• Torque:
CW
CCW
±1%
±1%
of reading, 10% to 100% of full scale
4
DTC12340
DIMENSIONS: LENGTH / WEIGHT
Length
Width
Depth
Weight
Model
(mm)
(mm)
(mm)
(kg)
DTC12340
335
121
56
2.2
DTC RANGE
TORQUE: (Display Range and Resolution as
shown below)
Square Drive
Overload
Model
ft - lb
in - lbs
Nm
(in.)
(Nm)
DTC12340
1/2
25.0- 2 50.0
300- 3 000
34.0- 3 40.0
425.0
OPERATING TEMPERATURE
0°F to 130°F (-18°C to 54°C)
STORAGE TEMPERATURE
0°F to 130°F (-18°C to 54°C)
MEASUREMENT DRIFT
TORQUE: +0.01% of reading per Degree C
HUMIDITY
Up to 90% non-condensing
BATTERY
Three "AA" Alkaline Cells, up to 40 hours continu-
ous operation
A/C ADAPTER (Not included)
A/C Adapter transformer,
Voltage Input: 90 to 240VAC, 50-60 Hz, 0.8A
P/N: DTCC1
Voltage Output: 9VDC, Current 2.2A
DEFAULT AUTO SHUT-OFF
After 5 minutes idle – (Adjustable, see Settings)
DTC12340
USER INSTRUCTIONS
BASIC FUNCTIONS (QUICK START)
FIGURE 1
BATTERY
CONDITION
1.PEAK
ON/OFF AND
RE- Z ERO BUTTON
PEAK TORQUE
RECALL BUTTON
UNITS BUTTON
½" x ⅜"
SOCKET ADAPTER
Install three fresh "AA" cells into battery holder.
DTC POWER ON SEQUENCE
Note: Do not turn on DTC while torque wrench is mounted to checker, otherwise torque zero offset
will be incorrect and DTC will indicate a torque reading when torque is removed. If this occurs,
remove torque wrench from DTC and re-zero by momentarily pressing POWER
1. Turn on DTC.
Momentarily press POWER
button. BAHCO logo is displayed followed by torque re-zeroing screen.
After re-zeroing, the torque screen is displayed.
2. Select mode of operation.
Toggle between PEAK, 1.PEAK and TRACK by repeatedly pressing ENTER
PEAK = Used to check dial and or electronic torque wrenches
1.Peak = Used to check click style torque wrenches
Track = Can be used to check dial and electronic torque wrenches
3. Select units of measure.
Toggle between IN-LBS, FT-LBS and NM by repeatedly pressing UNITS
4. Peak torque recall.
Recall last peak torque applied by pressing and holding RECALL
0. 0
TORQUE
DISPLAY
FT‐LBS
INCREMENT
BUTTON
DECREMENT
BUTTON
MODE SELECT,
MENU ENTRY
AND ENTER BUTTON
AUDIBLE
ALERT
½" FEMALE
TRANSDUCER
SOCKET
½" FEMALE
CYCLING
SOCKET
button.
button.
button.
R
button.
5
Tabla de contenido
loading