Filters; Important - Hoover HUSHTONE CH34006 Manual Del Usuario

Ocultar thumbs Ver también para HUSHTONE CH34006:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Filters

WARNING
OPERATE VACUUM WITHOUT BOTH INLET FILTER AND FINAL FILTERS IN PLACE.
HEPA MEDIA FINAL FILTER
The final filters assist in the filtration process to return cleaner air to the room. There are 2 HEPA
Filters, one on each side of the backpack.
1
Remove filter door
by pulling rear tab
forward and rotating
out.

IMPORTANT

ON BOTH SIDES OF FILTER. THIS MAY TAKE UP TO 24 HOURS.
REPLACEMENT FILTER
Inspect HEPA Media Final Filter every month, rinsing when necessary. Check for
wear of media and replace if pleats are damaged. Change filter regularly to maintain
maximum performance.
Part No. 440009096
16
TO REDUCE THE RISK OF PERSONAL INJURY – UNPLUG BEFORE CLEANING OR SERVICING. DO NOT
2
Pull filter out by the
frame. Hand rinse in
cold water under low
pressure. Rinse only
surface facing inside
of machine. Allow to
dry and reposition into
filter housing.
ALLOW FILTER TO DRY COMPLETELY BEFORE REPLACING. DRY FILTER ON EDGE SO AIR CIRCULATES
3
To replace filter door,
align the two forward
facing tabs and rotate
into place. Press rear
tab until door snaps
into place.

Capítulos

Tabla de contenido
loading

Tabla de contenido