6.2 Inflate the tire with the optional IT system
The optional system (IT system) is suitable for the inflation of vacuum tires
During this process, the noise may reach 85 dB. It is recommended to wear noise protection gear.
Fix the wheel on the large plate and connect the inflation head to the air valve.
Check the dimensional fit between the tire and the rim.
Check if the tire edge is fully lubricated and perform further lubrication if necessary.
Depress the foot pedal to the middle position.
Check the air pressure while inflating the tire until the pressure reaches the required value.
Warning: There is a risk of explosion.
The tire inflating pressure shall not be more than 3.5 bar (51 psi). If higher pressure is required, remove the
tire from the large plate and inflate it in the special protective cage. Do not exceed the inflating pressure
recommended by the manufacturer, and keep your hands and other body parts behind the tire during inflation.
The inflation procedure shall only be conducted by specially trained and authorized personnel. Other personnel
shall not work or stand near the tire changer.