The carbon filters should be replaced every 3 - 6 months or if they show signs of damage.
Abnormity and Solution
Fault
Light on, but motor does not
work
Light does not work, motor does
not work
Oil leakage
Shake of the body
Insufficient suction
The machine inclines
Cause
The leaf blocked
The capacitor damaged
The motor jammed bearing da-
maged
The internal with of motor off or
a bad smell from the motor
Beside the above mentioned, check the following:
Light damaged
Power cord looses
One way valve and the air ven-
tilation entrance are not tightly
sealed
Leakage from the connection of
U-shaped section and cover
The leaf damaged and causes
shaking
The motor is not tightly hanged
The body is not tightly hanged
The distance between the body
and the gas top too long
Too much ventilation from open
doors or windows
The fixing screw not tight enough Tighten the hanging screw and
The hanging screw not tight
enough
Solution
Get rid of the blocking
Replace capacitor
Replace motor
Replace motor
Replace lights
Connect the wires as per the
electric diagram
Take down the one way valve and
seal with glue
Take U-shaped section down and
seal with soap or paint
Replace the leaf
Lock the motor tightly
Fixed the body tightly
Readjust the distance
Choose a new place and resemb-
le the machine
make it horizontal
Tighten the hanging screw and
make it horizontal
Tabla de contenido