Servicing The Tool - Ingersoll Rand SC Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Lubrication
Ingersoll- -Rand No. 10
Ingersoll- -Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter- -Regulator- -Lubricator
Unit (FRL):
Inside USA use FRL unit # C11- -03- -G00
Outside USA use FRL unit # C26- -C4- -A29
After each two hours of operation, if an air line lubricator is
not used, inject 1/2 to 1 cc of Ingersoll- -Rand No. 10 Oil into
the Air Inlet.
Model
335SC4
330SC4
325SC4
325XC4
(3I Extension)
330XC4
(3I Extension)
Tested in accordance with PNEUROP PN8NTC1.2
H
Tested in accordance with ISO8662
z
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.

SERVICING THE TOOL

Ingersoll- -Rand No. 68
SPECIFICATIONS
Speed
rpm
inches
35,000
1/4I
30,000
1/4I
25,000
1/4I
25,000
1/4I
30,000
1/4I
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
Emergency
Shut--Off
Valve
Lubricator
Regulator
Drain Regularly
H Sound Level
Collet
mm
Pressure
6
82.1
6
82.8
6
81.2
6
82.2
6
82.6
3
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
R
L
F
Filter
FRL
Compressor
(Dwg. TPD905- -2)
Vibration Level
z
dB(A)
Power
--------
--------
--------
--------
--------
2
m/s
3.7
2.1
1.8
2.4
1.9
Tabla de contenido