Operating Instructions
Operating The Tool
(Continued)
5. Always unload all fasteners before
removing tool from service.
Unloading is the reverse of loading,
except always disconnect the air
supply before unloading.
ADJUSTING THE FASTENER PENETRA-
TION
1. Regulate the air
pressure to 60 psi
at the tool.
2. Connect the air
supply and test for penetration by
driving fasteners into a sample piece
of wood. If the fasteners do not
achieve the desired penetration,
adjust the air pressure to a higher
setting until the desired penetration
is achieved. Do not exceed 100 psi
at the tool or durability of the tool
will be reduced.
CLEARING A JAM FROM THE TOOL
1. Disconnect the
air supply from
the tool.
2. Remove all fas-
teners from the
magazine (see
"Loading/
Unloading The
Tool"). Failure to do so will cause
the fasteners to eject from the front
of the tool when the nose assembly
is removed.
3. Remove (3) cap screws from the
nose of the tool. Remove nose
plate, spacer and Work Contact
Element (WCE) to expose jammed
fastener.
4. Reinstall nose assembly in reverse
order in step #3.
5. Make sure the trig-
ger and Work
Contact Element
(WCE) move freely
up and down with-
out sticking or binding.
Technical Support
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
Fastener And Replacement
Parts
WARNING
!
Hausfeld 18 gauge fasteners (or equiva-
lent - see Fastener Interchange
Information). Tool performance, safety
and durability could be reduced if
improper fasteners are used. When
ordering replacement parts or fasten-
ers, specify by part number.
Tool Repair
Only qualified personnel should repair
the tool, and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
Assembly Procedure For
Seals
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W non-
detergent oil or equivalent, must be
added through the air line before
testing.
movement
Use only
genuine Campbell
5
Model SB3232
www.chpower.com