Safety Thermostat; Rs-232 Communication - Selecta VACIOTEM-T Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTRUCTION MANUAL CODE 80152 REV E
Start frame
Address
Data
LRC
End frame
J
.P. SELECTA s.a.u.
DEC 2019

SAFETY THERMOSTAT

Vacuum ovens Vaciotem T and Vaciotem TV are equipped with
a safety thermostat (31) which prevents that heaters temperature
never reach at dangerous levels.
Never change the thermostat adjustment. It could cause unexpected
stops of drying processes.
Thermostat have a reset push button (32) that allows to let the
equipment ready to work elapsed some time. Nevertheless, if
thermostat disconnects many times the process, user should call
up to technical service.

RS-232 COMMUNICATION

RS-232 COMMUNICATION OVERVIEW
• 9600 bauds, 7 dat bits, 1 bit stop, without parity no handshake.
• Up to 15m of cable.
• Cable conection DTE to DTE 9 pins male.
• Protocol ASCII with LRC against transmition errors
• MASTER-SLAVE Communication (PC computer as a master).
• The device never sends anything if computer does not ask for
Start frame
Address
#
N
H
#
NN
Message
KK
<CR><LF>
• Messages start with character #.
• Device address must be included.
This field goes from 00 to 99, size always 2 bytes in decimal-
• Data field is the message.
• LRC is a calculated value to check good transmission.
• At the end of the frame always a CR (0D) followed by LF (0A).
• Slave device answers always by sending its address.
Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España
e-mail: [email protected] - website: www.grupo-selecta.com
(They can be modified without notice)
it.
Data
N
L
Message (n bytes)
=
ASCII (23)
=
01...99
=
Command + arguments
=
00..FF
=
ASCII (0D)+ASCII (0A)
ASCII format.
LRC
End frame
K
K
CR
H
L
1 byte
2 bytes
n bytes
2 bytes
1 byte
Tel 34 937 700 877 Fax 34 937 702 362
Page: 27
LF
Tabla de contenido
loading

Este manual también es adecuado para:

Vaciotem-tv40014894001490

Tabla de contenido