Faber HILTIS36WHNB Instrucciones De Instalación Información De Uso Y Cuidado página 31

Tabla de contenido
Cleaning metal grease filters
These can be washed in the dishwasher, and need to be cleaned
whenever the S1 LED comes on or at least once every 2 months
of use, or more frequently if use is particularly intensive.
Resetting the Grease Filter Alarm
• Turn the Lights and the Hood off.
• Press
and hold for at least 3 seconds, until LED flashes
three times in confirmation.
T1
T2
T3
Cleaning the Filters
• Open the Panel.
• Remove the Filters one at a time, pushing them towards
the back of the unit and at the same time pulling downward.
• Wash the Filters without bending them, and leave them to
dry completely before replacing. (If the surface of the filter
changes color as time goes by, this will have absolutely no
effect on the efficiency of the filter itself.)
• Replace the grease filters, taking care to ensure that the
handle faces forward.
• Completely dry the filters before reinstalling. Otherwise, left
over grease may heat and drip.
• Close the Panel.
Replacing Activated Charcoal Filter
They cannot be washed or regenerated, and must be
changed when LED S1 starts to flash, or at least once
every 4 months. The Alarm signal, if it has been activated,
only appears when the Hood Blower is turned on.
Resetting the alarm signal
• Turn the Lights and the Hood Blower off.
• Press
and hold for at least 3 seconds, until
LED flashes three times in confirmation.
T1
T2
T3
Cleaning the Filters
• Open the Panel.
• Remove the Metal Grease Filter.
• Remove the saturated Activated Charcoal Filters, as
indicated (A).
• Fit the new Filters, as indicated (B).
• Replace the Metal grease filters.
• Close the Panel.
S1
T4
S1
T4
1
2
3
A
B
31
Tabla de contenido
loading

Este manual también es adecuado para:

Hiltis36ssnb

Tabla de contenido