Sera Marin Biotop LED Cube 130 Instrucciones De Montaje Y Uso página 23

Acuario completo con led de bajo consumo
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Cleaning
The sera UV-C System must not be opened. Also, you
must not poke around in the inside with pointed or hard
items. If the unit is clogged and cannot be cleaned by rins-
ing with water you should replace the lamp along with the
casing.
Troubleshooting:
Problem
Control LED is not on
UV-C lamp is not on
Cloudiness/Algae remain unaffected
Technical Data:
sera UV-C lamp
Ballast
Transformer
Flow pump STP 1000
Pump performance
Warning
1. Children should be supervised to ensure that they do
not play with the appliance.
2. This appliance is not intended for use by persons (in-
cluding children) with reduced physical, sensory or men-
tal capacities, or lack of experience and knowledge, un-
less they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
Possible cause
No electrical supply
Cables are not properly connected
UV-C lamp faulty
Blue and black plug are inter changed
No bacterial cause, mineral cloud iness
UV-C lamp faulty/too old
220 – 240 V, 5 W
IPX8 (1 m / 3.3 ft.)
12 V 6 W UVPL
IN
230 V AC 50 Hz
OUT 12 V AC 650 mA
max. 1,000 l/h
(264 US gal./h)
IPX8 (1 m / 3.3 ft.)
Maintenance
The UV-C lamp should be replaced after approx. one year.
First disconnect all electrical parts from the mains supply.
Take the UV-C system out of the aquarium along with the
pump. Disconnect the lamp unit from the hose. Replace
the hose if necessary. Connect new UV-C lamp to a new
12/16 mm hose and secure with a cable tie. Connect the
pump in the same manner. Install lamp and pump in the
fourth chamber of the internal filter again and re-connect
the UV-C lamp outlet opposite of the water outlet.
Possible solution
Check plug
Plug in transformer
Check connections
Replace lamp unit
Connect correctly
Use a fine particle filter, water change
Replace lamp unit
3. The UV-C lamp must no longer be used if the mains
cable is damaged (see "Important warranty addendum").
Disposal of the unit:
Waste electrical and electronic equipment (WEEE)
must not get into domestic waste!
If ever the unit cannot be used anymore, the consumer is
legally obliged to hand in waste electrical and electron-
ic equipment (WEEE) separately from domestic waste,
e.g. at a collection point of his community/his district. This
ensures that waste electrical and elec tronic equipment
(WEEE) is expertly processed and that negative effects to
the environment are avoided.
Therefore electrical and electronic
equipment bears the following symbol:
Manufacturer warranty:
When following the directions for use the sera UV-C
System will perform reliably. We are liable for the freedom
from faults of our products for 2 years beginning with the
purchase date (exception: 12 months for the UV-C lamp).
We are liable for complete flawlessness at delivery. Should
usual wear and tear occur by use as intended by us, this is
not considered a defect. Warranty claims are also exclud-
ed in this case. Legal claims are of course not reduced or
limited by this warranty.
Please note the additional warranty information (*).
23
Tabla de contenido
loading

Tabla de contenido