14.3.1 Check hydraulic oil
Waste oils are toxic and must not be released into the environment!
Contact your local authorities for information on proper disposal.
14.4 Gearbox
14.4.1
Check gearbox oil
The gearbox is pre-lubricated and sealed at the factory. Unless there is evidence of leakage or service
has been performed on the gearbox, no additional lubricate should be required until 50 hours of use.
For future use, check the oil level after every 50 hours of use.
Waste oils are toxic and must not be released into the environment!
Contact your local authorities for information on proper disposal.
If you remove the oil level plug and no oil flows out, please add oil and then screw the oil level
plug.
NOTICE:
recommended motor oil: GL-5, GL-6, SAE80W-90. Do not use synthetic oil!
If you want to replace oil, place the machine on a level ground. The machine must be stopped and
still warm. Unscrew the filter cap and the drain plug. When the oil is drained, replace the drain
plug, fill up with fresh oil and then replace the filter cap.
ZIPPER MASCHINEN GmbH
ZI-MD500HST
www.Zipper-Maschinen.at
NOTICE
1. Loosen the hydraulic pipe (2) to drain the old hydraulic
oil into a suitable container.
2. After the hydraulic oil tank has been completely
emptied, retighten the hydraulic pipe (2).
3. Remove the oil dipstick (1) and add the oil.
The recommended hydraulic oil is 10W AW32,
ASLE H-150 or HLP 32.
Oil capacity of the hydraulic system: see technical
data.
4. Check the correct oil level by means of the marking
(3) on the dipstick after filling.
NOTICE
MAINTENANCE
37