THERMOHEAT FA60 Serie Manual Del Usuario E Instrucciones De Operación página 4

Calentador de propano para construcción
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Dyna-Glo ProPane ForceD air construction Heaters
The heater is designed and approved for use as a construction heater under anS z83.7 CSa 2.14. it is hard
to anticipate every use which may be made of this heater.
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
your local authority can advise you about these.
IMPORTANT: read ThiS uSer'S Manual CareFully and CoMpleTely BeFore Trying
To operaTe or ServiCe ThiS heaTer. iMproper uSe oF ThiS heaTer Can CauSe
SeriouS injury or deaTh FroM Fire, exploSion and CarBon Monoxide poiSoning.
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. all the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount
of carbon monoxide. humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
3
PROPANE CONSTRUCTION HEATER
WARNING
: noT For uSe wiTh duCT work.
sPeciFications
Model   N o.
FA60   S eries
30,000   B TU/hr
Input   R aBng
60,000   B TU/hr
Type   o f   G as
Propane
Gas   S upply   P ressure   t o  
Cylinder   P ressure
Regulator   M aximum
Minimum   ( for   p urpose      
5psig
of   I nput   A djustment)
Manifold   P ressure
11"   W .C
1.4lbs/hr
Gas   C onsumpBon
2.8lbs/hr
Electrical   I nput
120V,   6 0Hz,   1 Ø  
Amperage     L oad
0.65amps
    U nload
3570rpm
Fan
    L oad
3300rpm
IgniBon
ConInuous   S park
Spark   G ap
0.16"   ( 4mm)
19.3"x8.3"x15.2"
Size   ( LxWxH)
(490x211x386)mm
Weight
14.3lbs   ( 6.48kg)
CHECK WITH YOUR LOCAL FIRE SAFETY
LPFA125   S eries
70,000   B TU/hr
125,000   B TU/hr
Propane
Cylinder   P ressure
5psig
11"   W .C
3.3lbs/hr
5.8lbs/hr
120V,   6 0Hz,   1 Ø  
0.7amps
3580rpm
3300rpm
ConInuous   S park
0.16"   ( 4mm)
25.59''x11.81''x16.64''                
(650x300x410)mm
20.72lbs                                                            
(9.4kg)
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Tabla de contenido
loading

Este manual también es adecuado para:

Lpfa125 serieRmc-fa60Rmc-fa60lRmc-fa60l-01Lpfa125Lpfa125l ... Mostrar todo

Tabla de contenido