ASSEMBLY INSTRUCTIONS
10. To install the battery (DD), unscrew the igniter
cap preassembled to burner assembly (C).
Insert battery (DD) into the igniter, ensuring
the positive "+" end faces
replace the igniter cap.
OPERATING INSTRUCTIONS
Checking for Leaks
a. Make leakage solution by mixing 1-part liquid dish soap and 3-parts water.
b. Spoon or brush several drops (or use squirt bottle) of the solution onto the gas hose/regulator and
regulator/cylinder and hose connections.
c. Turn on gas cylinder valve. Inspect the connections and look for bubbles.
1. If no bubbles appear, the connection is safe.
2. If bubbles appear, there is leakage. Loosen and re-tighten this connection. If it still leaks, please call
customer service.
outward,
then
12
10
C
-
+
Igniter