Turn off the water supply by turning off the water shutoff
valve, then disconnect the supply hose.
If you are using a rigid supply line you will need to
purchase a flexible supply hose to install the bidet seat.
8
Make sure the control lever on the bidet seat is at the
90˚ off position. Turn the water shutoff valve back on.
OFF POSITION
OPERATION
WASH FUNCTION
BIDET FUNCTION
LOW FLOW
HIGH FLOW
LOW FLOW
HIGH FLOW
7
Install T-shape adapter to the
fill valve and supply hose as
shown. Connect the included
connection hose with filter on
to the T-shape adapter and
the bidet seat inlet.
WARNING
Make sure the filter and
seal on the connection
hose are installed along
with the hose.
DO NOT OVERTIGHTEN
THE THREADED
CONNECTIONS.
The connections may be
broken or the threads may
be damaged if over torqued.
9
While sitting on the seat, rotate the control lever
forward or backward for functional testing. Also,
check the connectors to make sure there are no
leaks. If you find leaks retighten the connectors.
Keep the lever at the 90˚ position when not
in use. The wand cleans itself after each
use. For additional cleaning of the wand,
position the lever at 85˚ or 95˚ for a few
seconds and then reposition back to 90˚.
- 4 -
FILTER
A
D
GASKET
B
E
C
OFF AND SELF-CLEANING