Unpacking

Do not lift or move unit without appropriately rated equipment. Be sure
the unit is securely attached to lifting device used. Do not lift unit by
holding onto tubes or coolers. Do not use unit to lift other attached equipment.
After unpacking the unit, inspect carefully for any damage that may have occurred
during transit. Check for loose, missing or damaged parts. Check to be sure all supplied
accessories are enclosed with the unit. In case of questions, damaged or missing parts,
please call 1-855-504-5678 for customer assistance.
Do not operate unit if damaged during shipping, handling or use.
Damage may result in bursting and cause injury or property damage.
REQUIRED ITEMS - NOT INCLUDED
Oil

Installation

Turn engine off and key out. Release all pressure from the
system before attempting to install, service, relocate or
perform any maintenance.
Do not lift or move unit without appropriately rated
equipment. Be sure the unit is securely attached to lifting
device used. Do not lift unit by holding onto tubes or coolers. Do not use unit to lift other
attached equipment.
Never use the wood shipping skids for mounting the compressor.
PICKING THE LOCATION
Install and operate unit at least 18 inches from any obstructions in a clean, well
ventilated area. The surrounding air temperature should not exceed 100° F. This will
ensure an unobstructed flow of air to cool compressor and allow adequate space for
maintenance.
Do not locate the compressor air inlet near steam, paint spray, sandblast
areas or any other source of contamination.
NOTE: If compressor operates in a hot, moist environment, supply compressor pump
with clean, dry outside air. Supply air should be piped in from external sources.
TANK MOUNTING
The tank should be bolted into a flat, even, surface. Vibration isolators, supplied with
unit, should be installed under the tank leg brackets.
When using isolator pads, do not draw bolts tight. Allow the pads to absorb vibrations.
When isolators are used, a flexible hose or coupling should be installed between the
tank and service piping.
Failure to properly install the tank can lead to cracks at the
welded joints and possible bursting.
Series CE7003TD
Figure 2 - Location
Figure 3 - Isolator pad
www.campbellhausfeld.com