Assembly
ASSEMbLY TOOLS REqUIRED
Tools (not provided) for assembly:
-
(1) 10mm nut driver
-
(2) adjustable wrenches
FOOT ASSEMbLY (FIGURE 1)
Foot assembly kit includes:
-
(1) rubber foot
-
(1) bolt
-
(1) washers
Rubber Foot
Washer
Bolt
Figure 1 - Rubber foot installation
Use a nut driver to tighten bolt.
WHEEL ASSEMbLY (FIGURE 2)
Wheel assembly kit includes:
-
(2) wheels*
-
(2) axle bolts*
-
(2) lock washers*
-
(2) washers*
-
(2) nuts*
The items marked with an asterisk (*)
were shipped loose with the unit.
Nut
Lock
Washer
Washer
Wheel
Axle Bolt
Figure 2 - Wheel assembly
1. Wheel has an offset hub. With offset
hub facing axle iron, assemble axle bolt
through holes in wheel and axle iron.
2. Place adjustable wrench on axle
bolt. Using a second adjustable
wrench, tighten nut securely to
threaded part of axle bolt.
3. Repeat procedure with other side.
Wire
Power cord
Motor cord
Power cord
Motor cord
(✽) When the unit is not in operation
HANDLE ASSEMbLY (FIGURE 3)
Never use the
handle to lift the
unit completely off the ground. only
use the handle to lift one end so the
wheels may be used to move the unit.
Handle assembly kit includes:
- (1) handle
- (2) bolts
Handle
Bolt
Figure 3 - Handle Assembly
1. Insert ends of handle into tube
shaped brackets on tank.
2. Align screw holes.
3. Thread screw into hole until tight.
Installation
LOCATION
It is extremely important to install the
compressor in a clean, well ventilated area
where the surrounding air temperature
will not be more than 100°F.
A minimum clearance of 18 inches between
the compressor and a wall is required
because objects could obstruct air flow.
Do not locate the
compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination. This
debris will damage the motor
Household use only. Store indoors.
Minimum Gauge of Extension Cords for 120V Unit
Motor Amp
Rating Range
10-12 amp
12-14 amp
14-16 amp
3
✽ Wire and Terminal Guide
Color
Terminal
White
Line
White
Load
Black
Line
Black
Load
ELECTRICAL INSTALLATION
1. Check and tighten all bolts, fittings,
etc., before operating compressor.
2. Operate compressor in a ventilated
area so that compressor may be
properly cooled.
3. Compressor should be located where
it can be directly plugged into an
outlet, but if this is not possible, an
extension cord may be used. It should
be selected using the extension cord
Tank
chart on page 3 as a guide.
4. To avoid loss of power and
overheating, it is better to use
additional air hose instead of
extension cords to reach work area.
WIRING
1. Local electrical wiring codes
differ from area to area. Source
wiring, plug and protector must
be rated for at least the amperage
and voltage indicated on motor
nameplate, and meet all electrical
codes for this minimum .
2. Use a slow blow fuse type T or a
circuit breaker.
damage will result from inadequate
wiring, etc.
connections should be performed by a
qualified electrician. installation must
be in accordance with local codes and
national electrical codes.
NOTE: 120 volt, compressor can be
operated on a 120 volt, 15 amp circuit
under the following conditions:
a. No other electrical appliances or
lights are connected to the same
branch circuit.
Length of Cord
25 feet
50 feet
16
14
16
12
16
12
HM7110 Series
Hot
No
No
Yes
Yes
overheating, short
circuiting and fire
All wiring and
electrical
100 feet
10
10
10
www.chpower.com