ABITIG
Little
Type
Type of
cooling
®
ABITIG
Little
9
air
17
air
90
air
150
air
24 G
air
20
liquid
25
liquid
180W
liquid
260 W
liquid
24 W
liquid
Tab. 4
Product-specific torch data (EN 60 974-7)
Liquid-cooled torches
Tab. 5
Required cooling unit capacity
Load
ED
Electrode
DC
AC*
A
A
%
mm
110
80
35
0.5 - 1.6
140 100 35
0.5 - 2.4
90
60
35
1,0 - 2,4
140 100 35
1.0 - 2.4
110
80
35
0.5 - 1.6
220 150 100 0.5 -- 3.2
200 140 100 0.5 -- 3.2
180 130 100 1,0 - 3,2
240 170 100 1.2.0 - 3.2 7 - 18
140 100 100 0.5 - 2.4
*According to EN 60 974-7 the value for alternating current (AC) must be
given at 70% of the tested direct current value (DC).
All data refer to 4 m cable assemblies. For any further information regarding
the available cable assembly designs and performance data, please refer to
the current order documentation.
Gas flow
Cooling
Max. supply
temp.
l/min
°C
5 - 12
7 - 15
5 - 12
5 - 12
5 - 12
8 - 22
50
8 - 22
50
7 - 18
50
50
7 - 15
50
min. 800 W
3 Product description
Torch inlet
pressure
Min.
min.
max.
flow
l/min bar
bar
0.7
2.5
3.5
0.7
2.5
3.5
0,7
2,5
3,5
0.7
2.5
3.5
0.7
2.5
3.5
EN - 7