A M B I E N T H E A T I N G S O L U T I O N S
4. Unpacking the unit / packaging
Unpack the unit and the accessories carefully. When opening the packaging, do not use sharp objects that could damage the unit.
This product comes supplied in environmentally friendly packaging. All HEATSCOPE® packaging that comes into circulation either directly or via the
trade is certified in accordance with §6 of the German Packaging Directive. As a result, all HEATSCOPE® packaging can be disposed of in an environ-
mentally friendly manner in collection containers for packaging materials. The relevant legal regulations must be observed here. Further information is
available from the manufacturer.
Care information! Important! Clean the unit with a damp cloth before using it for the first time. Do not use cleaning products containing alkaline
substances such as sodium hydroxide or soap, surfactants or solvents/alcohol.
5. Installation instructions
The INDIVIDUAL options for installing the HEATSCOPE® radiant heater are shown in the diagrams on the first pages of this manual.
Ensure that the radiant heater is fixed securely to the installation surface. In terms of tensile and shear strength, the fixings must be able to withstand
at least 3 times the weight of the radiant heater (including accessories) that is to be installed. When installing the unit, use the correct screws and plugs
(supplied) for the surface.
Please bear in mind that you always need two fixing brackets to fix your unit safely. Please refer to the minimum installation dimensions for the unit
under „minimum distances".
It is mandatory to install the unit on a surface where it is well protected from any weather influences like rain and dust from above; so the HEATSCOPE
has to be installed under a roof, an overhang or in combionation with an optional available weather shield.
6. Operation, installation instructions and minimum distances
Once you have installed the unit, you can use it for the first time.
The HEATSCOPE® features an omnipolar „ON/OFF" switch. You can control the radiant heater manually using a selector switch on the unit itself or using
an IR remote control which comes supplied (depending on the model). The unit must be connected to a residual current circuit breaker and a fuse.
Install the unit only in indoor or outdoor areas that are well protected from any weather influences from above like rain and dust. The heater is protec-
ted from lateral spray water, but is has to be covered with a roof or a similar canopy like the optional available weather shield upwards.
The radiant heater must be installed at a height of at least 180 cm and at a distance of at least 40 cm from each adjacent wall. The distance between
the radiant heater and the rear surface must be at least 10 cm (wall) and 17 cm (ceiling – this distance can be achieved using the supplied fixing acces-
sories). Other protective measures may need to be taken in accordance with local fire safety regulations, e.g. for installation on cumbustible surfaces.
The radiant heater must not be installed directly below a power socket. The sides of the HEATSCOPE® must be at least 10 cm from any power sockets.
9. Care, maintenance and service
Before cleaning and maintaining your HEATSCOPE®, disconnect it from the power supply or, if buried cables are used, switch it off via the omnipolar
switch. Ensure that the unit has cooled down – wait at least 30 minutes after the last use before you start cleaning it.
All surfaces should be cleaned using a damp cloth only. Never use cleaning products containing alkaline substances such as sodium hydroxide or soap,
surfactants or solvents such as alcohol.
Use only a very soft cloth or a brush for the reflector and the heating elements.
The power cable or buried cable with omnipolar switch may only be replaced by a professional specialist electrical company enlisted or approved
by the manufacturer. Heating elements, other components or parts of the housing may only be replaced by a service organisation enlisted by the
manufacturer.
If you yourself or someone enlisted by you carries out repairs, they will not be covered by the guarantee. Improper repairs and incorrect installation or
operation shall invalidate the guarantee immediately.
8. Removal from service / disposal
When the unit reaches the end of its life, it must be removed from service by a specialist in accordance with the relevant regulations and steps must be
taken to ensure that it cannot be put into use again.
The unit must be disposed of professionally and in an environmentally friendly manner. The relevant legal regulations must be observed.
EN
Tel.: +49 8104 647090 · Fax: +49 8104 647099 · E-Mail:
[email protected] · www.munich-home-systems.de