SOMFY animeo Guia De Instalacion página 8

Ocultar thumbs Ver también para animeo:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
EN
A
PICTURES
[1] animeo Power Supply DC (Ref. 1860093)
B
MOUNTING
Mounting in electrical cabinet, false ceiling or floor
or wall mounting. Make sure the unit is mounted
on a solid surface to securely fix the unit.
The unit shall be mounted in such a way, that the
back side becomes inaccessible.
[1] Choose the optimal location: flat and large
surface
[2] Select the relevant screws according to the
material of the mounting site and mount the
animeo Power Supply DC.
Mains connection shall not be accessible after
correct installation.
CHARACTERISTICS
Supply voltage
Max. current consumption
Output voltage
Max. output current
External overcurrent protection
Max. operating altitude
Operating temperature
Material of housing
Housing dimensions (w x h x d)
Weight
Degree of protection
Protection class
Pollution degree
Overvoltage Category
CABLE
Connection
220 - 240 V AC
24 V DC
220 - 240 V AC / 50/60 Hz
0.8 A
24 V DC ⎓
2.5 A (100 % permanent), 4.5 A (intermittent operation t
16 A fuse required
2000 m above sea level
0 °C to + 45 °C
PC/ABS
130 x 180 x 62 mm
460 g
IP 20
II
2
II
Cables
Min.: 2 x 1.5 mm
/ 16 AWG
2
Max.: 2 x 2.5 mm
/ 14 AWG
2
Min.: 2 x 1.5 mm
/ 16 AWG
2
Max.: 2 x 2.5 mm
/ 14 AWG
2
C
WIRING
[1] Use cable tie and cable grommet!
[2] Tool for all terminals
[3] Wiring diagram
D
MAXIMUM OUTPUT CURRENT
[1] 2.5 A (100 % permanent),
4.5 A (intermittent operation
t
3 min./t
on
Temperature-resistance
+ 90 °C
+ 90 °C
3 min.)
off
3 min./t
3 min.)
on
off
Max. distance
10 m
10 m
animeo POWER SUPPLY DC . REF. 5010767C -
7/18
loading

Este manual también es adecuado para:

1860093