Jandy
®
FloPro™ Variable-Speed Pump Series VS-FHP
Symptom
Pump will not start.
Variable-Speed Controller LCD is
not displaying information
or
pump LEDs are not illuminated.
Controller displays "Pump not
connected".
Fault message appears on
controller display.
|
Installation and Operation Manual
No power to pump.
Make sure pump is properly connected to high voltage. LED on top of electronics enclosure
should be illuminated. See Section 3.2, Electrical Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See Section
3.2, Electrical Installation, in this manual.
Improper pump address setting.
Make sure that pump dip switches 3 and 4 are set properly for the installation. Both
should be OFF for use with Variable-Speed Controller or set to the proper address when
connected to an AquaLink
®
Pump Dip Switch Settings, in this manual.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how to
correct fault, contact technical support at 800.822.7933.
Incorrect dip switch setting.
Make sure pump dip switches 1 and 2 are both ON. See Section 3.3, VS-FHP Pump Dip
Switch Settings, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See Section
3.2, Electrical Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See Section
3.2, Electrical Installation, in this manual.
Improper pump address set.
Ensure pump dip switches 3 and 4 are set properly for the installation. Both should be OFF
for use with Variable-Speed Controller or set to the proper address when connected to an
AquaLink
RS controller or an AquaLink PDA. See Section 3.3, VS-FHP Pump Dip Switch
Settings, in this manual.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how to
correct fault, contact technical support at 800.822.7933.