Main Features - Comelit 1456B Manual Del Usuario

Ocultar thumbs Ver también para 1456B:
Tabla de contenido
Warning
• This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Cut off the power supply before carrying out any maintenance procedures.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in
the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems,
by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
Article 1456B is a multi-apartment gateway that:
can serve up to 200 apartments, with a
maximum of 15 slave devices per apartment;
answer calls from a external unit via a virtual
door entry monitor App for smart phone/tablet
or using a normal GSM or landline telephone;
incorporates the SIP protocol to enable
telephone calls via SIP server or via virtual lines
purchased from a SIP services provider;
allows up to 4 simultaneous audio/video calls;
can be configured remotely from a web
interface.
Description
See fig. 1 on page 4.
1. B Ethernet port ("POE") for ViP system riser
input (default addressing: "Autoip").
2. Dip switches for the procedures "Reboot with
predetermined network settings" and "Restoring
factory settings".
3. Power supply input via Art. 1441, Art. 1441B.
4. CV1 and CV2 for setting port A2.
page 4)
5. CV3 and CV4 for setting port A3.
page 4)
6. A4 non POE Ethernet port for PC or router
connection (default: "Static IP address"
192.168.1.200, netmask 255.255.255.0).
7. A3 non POE settable Ethernet port "POE"
(default: "Static IP address" 192.168.1.200,
netmask 255.255.255.0). Set the port as "POE"
(see "Settable POE") if you want to connect
devices that require a power supply (door
entry monitors, for example).
8. A2 non POE settable Ethernet port "POE"
(default: "Static IP address" 192.168.1.200,
netmask 255.255.255.0). Set the port as "POE"
(see "Settable POE") if you want to connect
devices that require a power supply (door
entry monitors, for example).
9. A1 Ethernet port "POE" (default: "Static
IP address" 192.168.1.200, netmask
255.255.255.0).
Min/max power consumption (mA) 50mA
Configuration
√ This operation requires a PC loaded with the
software ViP Manager version 2.5.0 or later
(downloadable from the website
pro.comelitgroup.com).
√ An active internet connection is also required.
Connection
Article1456B has 2 network interfaces, A and
f
B, labelled for easy identification, which can be
(see fig. 2 on
configured separately to meet different system
requirements. Depending on the type of system,
(see fig. 2 on
connect the devices as shown
on pages 6-7.
ViP NETWORK + INTERNET CONNECTION
NETWORK
Take particular care with regard to the
network interface settings and do not
configure interfaces A and B with the same
addresses or similar parameters: each IP
address must be unequivocal, the addresses
of the interfaces A and B must not belong to
the same subnet.
SYSTEM WITH SINGLE NETWORK
All system devices form part of a single
network, so it it is only necessary to configure
interface A. In this case, DO NOT the alter the
configuration of interface B.

MAIN FEATURES

Compatible system ViP
DIN rail mounted Yes
DIN modules (no.) 4
Power supply voltage 48Vdc - 56Vdc
Operating temperature (°C) +5°C to +40°C
Operating relative humidity 25% / 75%
IP protection rating IP30
in figs. 4 and 5
9
Tabla de contenido
loading

Tabla de contenido