Genius LYNX 06 Advertencias Para El Instalador página 28

Ocultar thumbs Ver también para LYNX 06:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
4.
When value "00" appears on the display, cancellation has been done.
5.
Press key P1 again, and wait for 60 seconds, to return to normal operation.
6.
Give an OPEN impulse to perform a cycle.
Follow the procedure below to start up the system for the first time:
Power up the automated system and check that all the LEDs are in the situation described in paragraph 8.
1.
2.
Make sure that the display shows value "– –".
3.
Adjust the operating parameters, as described in paragraph 10.
4.
When you have finished adjusting the parameters, give an OPEN/CLOSE impulse, using any impulse generator
connected to this input, or the radio control if already memory-stored.
5.
The control unit starts an OPENING manoeuvre, until the opening travel limit device is reached and the display
shows value "OP".
During this stage, the control unit does not perform any slow-down.
If the automated system does not move and the display shows value "OP", this means that it is performing a
closing manoeuvre and the motor wires must be reversed. Give a RESET command by pressing push-button
P5, cut power and reverse the wires connected to terminals 6 & 8. Restore the power supply and resume from
point 4.
6.
When the opening travel limit device has been reached, providing automatic re-closing has been enabled, the
control unit starts counting the pause time and the display shows value "tc". If automatic re-closure was not activated,
the automated system remains idle waiting for a new OPEN/CLOSE impulse, and the display shows value "OP".
7.
When the set pause time has elapsed, with automatic re-closure, or at the next OPEN/CLOSE impulse, without
automatic re-closure, the automated system starts the closing manoeuvre until the closing travel limit device is
reached. The display shows value "CL".
8.
During the closing manoeuvre, the control unit performs the set slow-down.
9.
When the closing stage has finished, the display shows value "– –" and the automated system is ready for normal
operation.
If the described procedure begins with the automated system half open or fully open, e.g. following a RESET
command, the control unit does not perform slow-down either during the closing manoeuvre. Command
another cycle and check if the automated system is operating correctly.
Whenever you access the display of the operating parameters, or if power is cut, during the first cycle the control
unit automatically performs the work cycle learning procedure. While the work cycle is being learned, the
automated system does not perform any slow-downs.
Two protective fuses are located on the control unit – see Lay-out. If one of these two fuses has to be replaced, observe
the specifications indicated in the following table:
Fuse
F1=T5A 250V 5x20
. START-UP
2. PROTECTIVE FUSES
Protection
Transformer primary
winding / Power to motor
26
Fuse
F2=T500mA 250V 5x20
Protection
Power to accessories /
Indicator Light

Capítulos

Tabla de contenido
loading

Tabla de contenido