Genius LYNX 06 Advertencias Para El Instalador página 26

Ocultar thumbs Ver también para LYNX 06:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
Display
Parameter
Value
Automatic reclosure: This parameter is used for selecting automatic re-closure, if any, of the automated system, and
the relevant pause time.
0
Automatic closure disabled
1
Automatic closure enabled with a 5 seconds pause
2
Automatic closure enabled with a 10 seconds pause
3
Automatic closure enabled with a 20 seconds pause
4
Automatic closure enabled with a 40 seconds pause
c
5
Automatic closure enabled with a 60 seconds pause
6
Automatic closure enabled with a 90 seconds pause
7
Automatic closure enabled with a 120 seconds pause
8
Automatic closure enabled with a 180 seconds pause
9
Automatic closure enabled with a 240 seconds pause
Behaviour of the OPEN / CLOSE input: This parameter determines the behaviour of the OPEN/Close input.
A movement of the automated system corresponds to every impulse: Opens / Closes /
0
Opens...
d
The two movements of the automated system are separated by a stop: Opens / Stops/ Closes
1
/ Opens .....
2
The OPEN input commands only the opening of the automated system.
Condo function: If this function is activated, during the opening manoeuvre, the automated system ignores successive
impulses both of OPEN/CLOSE and of CLOSE until the system has completed the opening stage.
0
Condo function disabled
E
1
Condo Function Activated
Slow-down percentage: This parameter is used to select the length of the slowed down section before the travel limit
device intervenes. The length of the slowed down section is calculated as a percentage of the opening and closure
times.
0
No slow-down
1
Slow-down is 30% of the stroke
H
2
Slow-down is 40% of the stroke
3
Slow-down is 50% of the stroke
Heating function: If you activate this function, the control unit feeds the motor at a very low voltage in order to maintain
the motor at a temperature above ambient temperature. This function is active only when the automated system is
closed at rest, and if an OPEN command is sent, the function is interrupted.
0
Function disabled
1
Function enabled – a heating cycle every 5 minutes
M
2
Function enabled – a heating cycle every 15 minutes
3
Function enabled – a heating cycle every 30 minutes
4
Function enabled – a heating cycle every 40 minutes
Immediate closure: This function is active only when the function can only be activated combined with function logics
with Automatic re-closure, Automatic, Step-by-step automatic or Condo, and with the safety devices active only in
closure "y0".
With this function activated, and while the automated system is open in pause mode, when a change in the state of
the safety devices' is detected, e.g. when transiting in front of the photocells, the automated system closes immediately
without waiting for the pause time to elapse.
0
Immediate closure disabled
o
1
Immediate closure activated, but only with "y0"
Description
24

Capítulos

Tabla de contenido
loading

Tabla de contenido