Xylem Jabsco 31295 Serie Manual Del Usuario página 3

Bomba automática para sistema de agua potable
Ocultar thumbs Ver también para Jabsco 31295 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Fire hazard. Wiring must comply with
WARNING
!
applicable electrical standards and include
a properly sized fuse or circuit breaker.
Improper wiring can cause a fire resulting in
injury or death.
IF YOU ARE NOT FAMILIAR WITH APPLICABLE
CAUTION
ELECTRICAL STANDARDS, HAVE THE UNIT INSTALLED BY A
QUALIFIED ELECTRICIAN.
Figure 5.
Red (+)
CAUTION
Suggested wiring information is given as a reference. For proper
information, please reference ABYC E-11, AC and DC Electrical
Systems on Boats guidelines.
Wire Size
Table
Pump
Voltage
12 VDC
24 VDC
CAUTION
Motor case could get hot during extended
operation. Prolonged contact with skin may cause a burn.
CAUTION
Install a Pumpgard
location (for inspection and cleaning) between the tank and
pump inlet in order to protect valves from debris.
Operation
• Fill water tank
• Open all faucets
• Turn pump switch "ON"
Figure 6.
• When water is free of air, turn all faucets off beginning with
the faucet closest to the pump (Figure 6)
Important: Do not operate the pump more than 15 minutes
continuously.
Fuse
Total Wire Length - feet (meters)
0 - 20 ft
(0 - 6 m)
#14 AWG
#12 AWG
(2.5 mm
)
2
#16 AWG
#14 AWG
(1.5 mm
)
(2.5 mm
2
Initial Start Up
Demand Off
Demand On
Black (-)
Switch
20 - 35 ft
35 - 55 ft
(6 - 9 m)
(9 - 12 m)
#10 AWG
(4 mm
)
2
#12 AWG
)
2
strainer in an accessible
TM
Battery
(6 mm
)
2
(4 mm)