2.
TECHNICAL DATA
2.1 TECHNICAL DATA
Thermal power
Natural gas
(Family 2)
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
(1) Reference conditions: Temp. 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
For gas family 3 (LPG) ask for separate kit.
COUNTRY
GAS CATEGORY
II2Er3P
2.2 OVERALL DIMENSIONS
350
33
Length available using a separate kit.
Combustion head extension, supplied separately.
2.3 WORKING FIELD
4.0
3.0
2.0
1.0
0
50
60
D5079
50,000
2748
(1)
58 / 81 – 175 kW
Net heat value: 8 – 12 kWh/Nm
Pressure: min. 20 mbar
Single phase, 230 V
230V / 1.35 A
5 µ F
Primary
230V / 1.8A
0.24 kW
FR
DK - AT - GR - SE - IT
II2H3B/P
Burner
63
(as EN 676)
80
100
75,000
100,000
-
50,000 / 70,000 – 150,500 kcal/h
3
-
-
max. 100 mbar
~
±
10%
50Hz
-
Secondary 8 kV - 30 mA
LU
DE
II2E3B/P
II2ELL3B/P
120
389
280
379
67
120
140
125,000
Puissance thermique
2
GB
7,000 – 10,340 kcal/Nm
GB - IE - ES - PT
II2H3P
Flange
170
D4159
160
180
kW
150,000
kcal/h
3
NL
II2L3B/P