EMS.book Seite 8 Dienstag, 23. August 2005 8:38 08
Machine Elements
1 Switch
2 Oscillation frequency selector
3 Fixation element
4 Adapter for round attachment
5 Symbol on the cutting blade
6 Supplied accessories
Allen key (6a)
Sharpening stone (6b)
Not all of the accessories illustrated or described are included
as standard delivery.
Intended Use
This power tool is intended for:
commercial use in industry and trade,
EMS 1.6: for trimming plastic beads, e. g. in the vehi-
cles sector, for cutting out elastic sealants and marble
trass joints,
EMS 2.0: for sawing thin sheet metal, wood and plastic
parts, and for sanding smaller areas, corners and
edges, for application using the accessories given in this
instruction manual, or those recommended by Würth.
The user is responsible for damage caused by usage
other then intended.
Tool Specifications
EMS 1.6
Article number
0702 697 X
Rated input
400 W
Output
220 W
~
Current type
1
Oscillations
11 000 –
18 500 /min
Weight
1.25 kg
Class of protection
/ II (Protective
insulation)
Angle of oscillation1.6°
Mounting the tool
Before any work on the machine itself, pull the
mains plug.
Always wear protective gloves.
❏ Unscrew the fixation element 3.
The inner thread M 6, the drive shaft holder and the fix-
ation element must be clean.
❏ Tighten the fixation element 3 with the provided
Allen key.
For adopting a comfortable working position the tool
can be fastened on the drive shaft at 30° intervals.
8
The sanding plate can be fastened onto the drive shaft
in any position. The adapter 4 is required for working
with the sanding plate.
Sharpen the cutting blade at the lowest frequency
before each application with a sharpening stone. This
also applies for new cutting blades.
The cutting blades marked with a symbol 5 gmay
only be operated as indicated.
Switching On and Off
First check that the cable and plug are not dam-
aged.
Switching on: Slide switch 1 forwards (I).
Switching off: Slide switch 1 backwards (0).
Set the oscillating frequency
Using the oscillation frequency selector 2, the optimum
oscillation frequency can be set according to the appli-
cation and the accessory used.
Cutting blades for the vehicles sector
The cutting blades for the vehicles sector are to be
mounted as shown in the enclosure.
A Cutting blades, straight and curved.
B Cutting blades, bent at right angles.
C Cutting blades, U-form.
EMS 2.0
D Scraping knife.
0702 698 X
E Scraping knife.
400 W
F Cutting blade with stop roller.
220 W
The straight, curved or cropped cutting blades must be
~
1
held at right angles to the window flange.
11 000 –
With the U-shaped cutting blades make sure that the
18 500 /min
base of the cutting blade is guided parallel to the vehicle
1.25 kg
windscreen.
/ II (Protective
The scraping knife serves for levelling out glue spots on
insulation)
the window flange or windscreen. Before re-gluing the
vehicle windscreen, the remaining bead is to be levelled
2.0°
to approx. 2 mm.

Maintenance and Cleaning

Before any work on the machine itself, pull the
mains plug.
Carry out the following once a week, or more often if
the power tool is used more frequently:
❏ Clean the venting openings.
❏ Blow out the motor space from outside with dry com-
pressed air.
Starting Operation
Operating Instructions