90564808 AS1500.qxd:??????-00 BDL500 laser
This is stored on the front of the unit (fig. E).
• To use the high volume adaptor (24), remove it from the
high volume inflate connection.
• Remove the high volume hose (7) from the storage location.
• Remove the tapered nozzle (18) from the end of the
high volume hose (7).
• Fit the high volume adaptor (24) to the end of the high
volume hose (fig. F).
Many inflatables have an internal flap that prevents air loss
during inflation, especially air mattresses. Unless this flap is
displaced by the nozzle the inflatable will not inflate. Push
the nozzle firmly into the valve to make sure that you push this
flap out of the way.
WARNING:
Risk of Bursting. Excessive air pressure may
cause a hazardous risk of bursting or personal injury. Check
the manufacturer's maximum pressure rating for items being
inflated.
Note: If the pressure rating for the item being inflated is above
100 psi, note that the maximum run time is 10 minutes, leave
to rest for 20 minutes before re-use.
OPERATING THE INFLATOR (FIGURE G)
WARNING:
Do not operate the inflator when the car
engine is running.
Note: Make sure that your 12 Volt accessory socket is live. On
some vehicles the accessory socket may only become live
when the ignition key is in the accessory position.
To power the display from the 12Vdc adapter:
• Always fully extend the 12 Vdc cord before each use.
• Connect the 12 Vdc adapter (8) into your vehicles 12 V
accessory socket.
• Switch the main power switch (1) to the inflate position (c) to
power up the LCD.
To power the LCD from the internal battery (cordless
operation):
• Switch the main power switch (1) to the inflate position (c) to power up the LCD.
WARNING:
Risk of Bursting. Do not leave unit running unattended. Overinflation of
tires and other items could result in serious injury and property damage.

QUICK START

WARNING:
Never leave inflator running unattended in this mode. In can burst car
tires and other items.
To use your inflator immediately you can do so without setting the automatic shut-off
feature.
• Switch the main power switch (1) to the inflate position (c fig. G).
• To switch between the different units (PSI, BAR or KPA) press - & + buttons (21,23)
together until the required units are displayed.
• Connect the universal valve adaptor (6) and an accessory, if required, to the item to be
inflated, making sure that the lever (19) of the valve adaptor is in the down position to
lock it in place.
Note: Make sure that the universal valve adaptor is correctly fitted to the item to be
inflated.
• To start the inflator press the power button (22) on the LCD.
• When the item is inflated as required or to stop the inflator at any time press the power
button (22) on the LCD.
• Remove the hose from the item and store it on the unit.
• Turn the main power switch (1) to the off position (b fig. G).
5/18/10
9:56 AM
E
F
G
7
Page 7
24
18
24
20
a
c
b
1
21
22
23