Dell PowerEdge 2950 Guia De Inicio Rapido página 14

Ocultar thumbs Ver también para PowerEdge 2950:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Physical
Rack
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
12
Getting Started With Your System
8.656 cm (3.40 in)
44.7 cm (17.6 in)
75.68 cm (29.79 in)
26.76 kg (59 lb)
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing) with a maximum
humidity gradation of 10% per hour
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)
Tabla de contenido
loading

Este manual también es adecuado para:

Ems01

Tabla de contenido