2.2 - ACCESSORIES SUPPLIED WITH THE UNIT
Accessory
1 - Support plate
GB
2 - Instructions
3 - Dowels
2.3 - WEIGHT
Net weight (kg)
MPW1-2
MPW3-4
MPW1-2
MPW3-4
3 - INSTALLATION OF THE UNIT
3.1 - CHOOSING THE LOCATION
• Select the location for the unit on the basis of the following
criteria:
- The device is intended for installation in sheltered premises
(IP 20). Do not install in very damp places or exposed to
projHigh speedections of water.
- Do not place above electrical sockets.
- The air intake and blowing grilles must be free from any
obstacle so that blowing can occur correctly in the whole
room.
- The wall on which the air handler will be fi xed must be
suffi ciently thick for there not to be any resonance and so
as not to produce any noise.
- Provide for the pipes and electric cables.
- It is essential to leave the clear space around the unit (see
drawing).
3.2 - INSTALLATION OF THE SUPPORT PLATE
• Remove the mounting screw
from the support plate.
• Press at the points indicated
by a triangle to unhook the
plate's two lugs.
• The unit may be connected at 5
different points:
- on either the right or left-hand
side,
- at either the right or left-hand
rear,
- on the lower right-hand side.
3
ty
Q
Use
1
Wall support for the unit.
2
Installation instructions.
Operating instructions.
6
For fi xing the support plate.
Packed weight (kg)
8
10
12
14
A
B
270
805
285
995
Accessory
4 - Screws
5 - Seals
6 - Remote control unit
2.4 - DIMENSIONS
C
C
177
206
- Do not install units with electric heating near combustible
materials or surfaces.
• Use the support plate as a jig to locate the rear outlets.
Place the plate level against the wall and mark the hole to be
made.
For an outlet at the left-hand rear of the unit, use the plate's
most outside mark.
The Ø 65 mm
h o l e
i n
t h e
u p p e r
r i g h t -
hand corner of
the plate can
also be used
thus allowing
the tubes to exit
straight into the
wall.
• Mount the plate
on the wall using
t h e s u p p l i e d
s c r e w s
a n d
dowels.
T o
a v o i d
vibrations, ensure that the panel is mounted securely against
the wall.
ty
Q
Utse
For fi xing the support plate
6
with the dowels.
2
Connection of fl exible tubes
on the installation
(Ø 1/2" - 15 x 21)
1
Remote control unit
B
Ø 65 mm (MPW1-2)
NO
YES
111
NO