M. chEck SEnSorS
Go to
. Wind and sun sensors
Sensors status
should normally show a value higher then zero.
If that is the case, then everything is fine. If it's
very dark use a flashlight on the sun sensor to
simulate sun and check the value. If there's
no wind just turn the windmill manually and
check the value. If you have more then one
sun and/or wind sensor make sure that the
corresponding sensor is connected to the correct input. The easiest way of doing this is to
cover one sensor and then check the value/s.
n. ErrorS
Check
if any errors.
Error list
If yes, consult the owners manual.
o. SEttingS
The settings depend on the functions to be used. For detailed information, please see the
owner's manual.
The minimum settings are listed below:
l Disable functions that are not to be used. Especially important for wind, sun and heat
functions as they will generate errors if the referring sensor is not connected.
l Sensor allocation for wind and sun, if more then one sun and/or wind sensor are used.
l Wind threshold. For exact values please contact the solar protection supplier.
The table below is for guidance only:
Type
Façade awning / Screen
External Venetian blind
Folding arm awning
l If Alarm function is to be used, enable function.