Black and Decker BDP2600 Manual De Instrucciones página 14

Ocultar thumbs Ver también para BDP2600:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Engine
Consult the Engine Owners Manual for
the man u fac tur er's recommendations
for any and all maintenance.
Pump
NOTE: The pump was filled with oil at
the factory.
Change pump oil after the first 10
hours of operation and every 250 hours
thereafter.
To Check Oil
The oil level should
come to the dot in
the middle of the
sight glass (AA).
how To Change
Pump Oil
1.
Loosen pump
oil fill plug (BB).
2.
Place a con-
tainer under the oil drain plug
(CC).
3.
Remove pump oil drain plug.
4.
After oil is drained, replace oil drain
plug. Tighten securely.
Remove pump oil plug and fill with
5.
8.5 oz. (251 ml) of 30W non deter-
gent oil.
6.
Replace pump oil plug and tighten
securely.
Nozzle Cleaning
If the nozzle becomes clogged with for-
eign materials, such as dirt, excessive
pressure may develop.
becomes partially clogged or restricted,
the pump pressure will pulsate. Clean
the nozzle immediately using the nozzle
kit supplied and the following instruc-
tions:
1.
Shut off the pressure washer and
turn off the water supply.
2.
Pull trigger on gun handle to relieve
any water pressure.
3.
Disconnect the spray wand from
the gun.
4.
Remove the high-pressure nozzle
from the spray wand. Remove any
obstructions with the nozzle clean-
ing tool provided and backflush
with clean water.
5.
6.
7.
8.
BB
how to Clean the Water Inlet Filter
This screen filter should be checked
periodically and cleaned if necessary.
AA
1.
CC
2.
3.
NOTE: Do not operate pressure washer
without filter properly installed.
Engine
If the nozzle
Consult the Engine Owners Manual for
the manufacturer's recommendations
for storage.
Pump
The manufacturer recommends using
a pump protector/winterizer when
storing the unit for more than 30 days
and/or when freezing temperatures
are expected. A pump protector/
winterizer is availabe at the store where
the pressure washer was purchased.
If a pump protector/winterizer is not
available, RV antifreeze needs to be
run through the pump as outlined in the
steps below.
14- ENG
Direct water supply into spray wand
to backflush loosened particles for
30 seconds.
Reassemble the nozzle to the
wand.
Reconnect spray wand to gun and
turn on water supply.
Start pressure washer and place
spray wand into high pressure set-
ting to test.
Remove filter by
grasping end and
removing it from
water
inlet
of
pump as shown.
Clean
filter
by flushing it with water on both
sides.
Re-insert filter into water inlet of
pump. NOTE: Cone side faces
out.
STOrAGE
Tabla de contenido
loading