Assign Load Types; Address The Circuit Selector - Lutron GRAFIK Eye 4000 Serie Manual De Instalación

Ocultar thumbs Ver también para GRAFIK Eye 4000 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29

Assign Load Types

Assigning load types is done using the circuit selector located in each panel.
To view present load types:
Press button 5 to step through the Value displays until Load Type LED lights. Use buttons 1 and 2 to view present 
load type of each circuit. Note that ' - - - ' in the Value display means a load type is not assigned to the circuit. If 
load types are already assigned, compare them to the circuit directory (if provided). If there are no changes to be 
made, go to page 13, Assign Primary Zones.
To change load types:
A. Press and hold buttons 1 and 5 until SELECT VALUE LED blinks once per 
second.
B. Press button 5 until the Load Type LED lights.
C.  Choose circuit number with buttons 1 and 2.
D. Use buttons 3 or 4 to display the load type (see below) in Value window.
E.  Repeat steps C and D for each circuit.
F.  Press and hold buttons 1 and 5 until the VIEW VALUE LED lights.
Load Type Display
The load type is shown in the Value window. Use buttons 3 and 4 on the 
circuit selector to scroll through the choices and find the appropriate type.
- - - 
Unassigned (All intensities except 0 = On)
1 - 1 
Incandescent, Tungsten
2 - 1 
Fluorescent: Lutron Hi-Lume FDB or Eco-10
2 - 2 
Fluorescent: Lutron Tu-Wire
2 - 3 
Fluorescent: 0-10 V, with TVM module
2 - 4 
Fluorescent: PWM, with TVM module
2 - 5 
  F luorescent: Tridonic
module
2 - 6 
  F luorescent: Tridonic
with TVM module
2 - 7 
DALI
, with TVM module
1
2 - 8 
  F luorescent: Tridonic
dimming curve), with TVM module
2 - 9 
  D ALI
 (logarithmic dimming curve),  
1
with TVM module
2 - A 
  F luorescent: 10-0 V (10 V = 1%;  
0 V = 100%), with TVM module
3 - 1 
Neon/Cold Cathode
5 - 1 
Electronic Low-Voltage
6 - 1 
Magnetic Low-Voltage
7 - 1 
Fan
8 - 1 
Motor
- - A 
Auto phase
Intensity broadcasts only; individual ballast addressing 
1 
not possible
Warning! Failure to correctly assign load type may 
damage loads–especially certain electronic transformers, 
electronic ballasts, and motors. Verify with transformer 
or ballast manufacturer that product can be dimmed 
with phase control dimming before setting to any load 
type other than non-dim.

Address the Circuit Selector

If you are using GRAFIK Liaison software, the circuit selector must be 
addressed to download information. 
A. To set or change the address, press and hold buttons 1 and 5 until the 
Select Value LED flashes once per second.
B. Press button 5 on the circuit selector until "Ad" is displayed in the Circuit 
window.  If the Value window displays an address other than '–', the address 
has already been set (proceed to Step D).
C.  Use button 3 or 4 to assign an address (1-512) to the circuit selector. This 
address should match the address in the job drawing.
D. Press and hold buttons 1 and 5 until the View Value LED lights.
Notes
•  Mark addresses on a circuit directory for future reference.
•  If 'LC' is displayed in the circuit window, the circuit selector is locked out. 
Contact Lutron for assistance.
12     GRAFIK Eye
 4000 Series Control Unit Installer's Guide 
®
®
 DSI, with TVM 
®
 DSI (electronic off),  
®
 DSI (logarithmic 
®
1 2 3 4
D
Data A OK
1 2 3 4
D
S
C
ELECT
V
V
IEW
ALUE
S
V
ELECT
Link A
Link B
1 2 3 4
D
S
V
ELECT
Circuit Level
Load Type
Data A OK
Zone Assignment
Zone Assignment
Low-End Trim
High-End Trim
1 2 3 4
D
Address
S
C
('Ad' displayed)
ELECT
Warning - Read instructions to set the Load
Type. Instructions show more load types.
Load Type Quick Reference:
--- Unassigned
1-1
Incandescent
V
V
IEW
ALUE
2-1
Fluorescent Lutron Hi-lume
S
V
ELECT
2-2
Fluorescent Lutron Tu-Wire
Link A
Link B
S
V
ELECT
Circuit Level
Load Type
Zone Assignment
Hi-2 Baud Rate
Zone Assignment
Low-End Trim
4 - 1 
  N on-Dim: All intensities except 0% = On  
High-End Trim
LINK 1
LINK 2
(Non-Ess)
Address
(first on, last off)
('Ad' displayed)
Warning - Read instructions to set the Load
4 - 2 
    N on-Dim: Intensities above 60% = On,  
Type. Instructions show more load types.
Load Type Quick Reference:
below 40% = Off (non-dim slider)
--- Unassigned
1-1
Incandescent
4 - 3 
  N on-Dim: All intensities except 0% = On  
2-1
Fluorescent Lutron Hi-lume
2-2
Fluorescent Lutron Tu-Wire
(first on, last off)
4 - 4 
  N on-Dim: All intensities except 0% = On  
(first on, last off)
Hi-1 and Lo Baud Rates
4 - 1 
  N on-Dim: 0-99% = Off;  
100% = On (last on, first off)
LINK 1
LINK 2
(Non-Ess)
4 - 2 
    N on-Dim: Intensities above 60% = On, 
below 40% = Off (non-dim slider)
4 - 3 
  N on-dim: 0-99% = Off;  
100% = On (last on, first off)
4 - 4 
  N on-Dim: 0% = Off, 0-1% = turn On, 
100-99% = turn Off (first on, first off)
1 2 3 4
D
Data A OK
1 2 3 4
S
C
ELECT
V
V
IEW
ALUE
S
ELECT
Link A
1 2 3 4
D
Link B
S
ELECT
Data A OK
Circuit Level
Load Type
Zone Assignment
1 2 3 4
Zone Assignment
D
S
C
Low-End Trim
ELECT
High-End Trim
Address
Warning - Read instructions to set the Load
Type. Instructions show more load types.
V
V
IEW
ALUE
Load Type Quick Reference:
S
V
ELECT
--- Unassigned
1-1
Incandescent
Link A
2-1
Fluorescent Lutron Hi-lume
2-2
Fluorescent Lutron Tu-Wire
Link B
S
V
ELECT
Circuit Level
Load Type
Zone Assignment
Zone Assignment
Low-End Trim
High-End Trim
5
C
D
Power OK
Data B OK
Link Link
A B
5
C
D
IRCUIT
1
2
Steps A and 
Circuit
F: Press and 
hold Buttons 
ALUE
1 and 5
3
4
Value
5
C
D
D
ALUE
ISPLAYED
5
(See Instructions)
Power OK
Data B OK
w/ Circuit Schedule
w/ Zone Capture
TM
Link Link
A B
5
C
D
IRCUIT
1
2
Circuit
3-1
Neon / CC
4-1
Non-Dim
FDB Ballast
ALUE
R
Ballast
TM
3
Value window
4
Value
D
ALUE
ISPLAYED
5
(See Instructions)
w/ Circuit Schedule
w/ Zone Capture
TM
(Essential)
Normal
Emergency
3-1
Neon / CC
4-1
Non-Dim
FDB Ballast
R
Ballast
TM
(Essential)
Normal
Emergency
5
C
D
Data B OK
Power OK
Link Link
A B
5
D
C
D
IRCUIT
1
Steps A and 
2
Circuit
D: Press and 
hold Buttons 
V
ALUE
1 and 5
3
5
C
D
4
Value
V
D
ALUE
ISPLAYED
Power OK
Data B OK
5
(See Instructions)
Link Link
A B
w/ Circuit Schedule
5
w/ Zone Capture
C
D
TM
IRCUIT
1
Circuit 
('Ad' displayed)
2
window
Circuit
ALUE
3-1
Neon / CC
4-1
Non-Dim
3
Assign 
FDB Ballast
R
Ballast
TM
4
address
Value
D
ALUE
ISPLAYED
5
(See Instructions)
w/ Circuit Schedule
w/ Zone Capture
TM
R

Solución de problemas

loading