5. ROUTINE AND PERIODIC MAINTENANCE

The instructions contained in this section relative to routine maintenance are for unqualified but trained personnel.
As far as regards periodic/scheduled maintenance, instructions are for qualified personnel.

5.1 BASIC SAFETY STANDARDS

This paragraph informs the machine user of the basic standards to follow before proceeding, in conditions of total safety, to
carry out routine maintenance operations

5.1.1 PRINCIPAL GUIDELINES

Before carrying out any maintenance operations, disconnect the machine from the power supply mains :
- Press the O/I button so that the DISPLAY switches off
- Remove the plug (if fitted)
- Remove voltage using the thermomagnetic switch
Use gloves to carry out maintenance in proximity to "High and Low Temperatures"

5.1.2 WARNINGS

Do not approach electrical parts with wet hands or bare feet.
Do not insert tools or other objects into the protection grids.
Do not remove safety devices (grids, decals, etc.) during maintenance operations.

5.1.3 EMERGENCY OPERATIONS IN THE EVENT OF FIRE

In the event of fire do not use water. Use an extinguisher to cool the affected area as quickly as possible.
5.2 EQUIPMENT CLEANING

5.2.1 CLEANING THE SURFACES

Use a damp cloth wherever possible to clean the outer or inner surfaces of the machine.
Do not use chemical agents and/or abrasive substances. Only use neutral detergents and lukewarm water.
Do not use tools that may scratch the surfaces and thus cause the formation of rust
Rinse with clean water and dry thoroughly.

5.2.2 CLEANING THE CONDENSER

This cleaning operation must be carried out by qualified personnel. For constant equipment performance, condenser cleaning
must be carried out regularly to avoid the build up and deposit of dirt, which will prevent the passage of air or water (for water-
cooled condensers).
Under normal conditions this operation should be carried out every two months. Cleaning may be carried out more frequently
according to the ambient conditions of machine use.
Cleaning can be carried out using the following: a screwdriver and a long-bristled brush or better, compressed air.
�� �
��