7.3 Explanations on recurrent checks
and inspections
The EMO KS-Mobil 400 l / 600 l / 980 l must be
inspected in accordance with ADR 6.5.4.4.1 a) at
intervals of not more than 5 years . This inspection
must check conformity to type, including the label-
ling as well as the internal and external condition
and the correct operation of the operating equip-
ment, and must satisfy the responsible authority.
The tank must also be inspected in accordance
with ADR 6.5.4.4.1 b) at intervals of at most
two and a half years . This inspection must check
the external condition and correct operation of the
operating equipment and must satisfy the responsi-
ble authority.
In accordance with ADR 6.5.4.4.2, all metal IBCs
for transporting liquid substances must be
subjected to an initial inspection (i.e. before the
IBC is used for transportation for the first time)
following repair and leak testing at intervals of at
most two and a half years .
8. Decommissioning
1. First, drain the tank completely (by means of the
pump via the delivery hose and delivery nozzle).
2. Disassemble the DT-Mobile into its constituent
parts.
3. Sort accordingly by material.
4. Dispose of in compliance with local regulations.
Danger
of environmental contamination through
residues in the tank.
Collect these residues separately and
dispose of them in compliance with local
environmental regulations
9. Warranty
Under our general terms and conditions of trade we
warrant that the equipment will be produced free
from defects in materials, functionality or workman-
ship.
These can be inspected at
http://www.cemo.de/agb.html
The warranty applies only under the condition that
the above operating and maintenance instructions
and all applicable regulations are closely followed.
Modification of the filling station by the customer
without consultation with the manufacturer CEMO
GmbH invalidates any claims under the statutory
warranty.
CEMO GmbH also accepts no responsibility for
damage caused by inappropriate use.
10. Inspection protocol
see back page
GB