Troubleshooting

If the machine does not collect the material in a satisfactory way (alarm beeps):
• The suction hose, tube or nozzle may be blocked.
Das Gerät ausschalten und die Blockade entfernen.
• The motor top may not have been correctly mounted, which
can cause a leak.
Start the machine and block the suction hose. Normally you
can hear a possible leak. Loosen the container clips of the
motor top, place the motor top correctly and lock the clips
again.
If the machine does not start:
• The fuses of the control circuit may have melted.
• The hand tool starts but the machine does not start.
The fuse may have melted
• The collection bag may be blocked.
If you collect very fine dust, the collection bag may block
before it is completely full. Replace the collection bag.
• The membrane filter may be blocked.
Clean the membrane filter as described in the chapter about
cleaning of filter during operation.
• The HEPA filter may be blocked.
Replace the filter as described in the chapter about change of
filters.
The replacement must be made by BONA AB, an authorized
BONA AB repair shop or a qualified person in order to avoid
hazards.