MENU A: SYSTEM CONFIGURATION AND OPERATING LOGIC SELECTION
Menu
Function
A1
SWING GATE
A2
OVERHEAD DOOR/ BARRIER
A3
SLIDING GATE
A4
1-MOTOR CONFIGURATION
A5
2-MOTOR CONFIGURATION
STEP-BY-STEP WITH STOP
A6
LOGIC
A7
STEP-BY-STEP LOGIC
AUTOMATIC/CONDOMINIUM
A8
LOGIC
A9
DEAD MAN'S LOGIC
NB: E = function enabled. An enabled logic consequently disables the other ones of the same group
Status
Description
Configures the system for a swing gate.
E
Configures the system for an overhead door or barrier.
E
Configures the system for a sliding gate.
E
Configures the system for 1 motor.
In this mode, the outputs of motor 2 can be used as courtesy light
timed to 3 minutes.
E
WARNING: If using the outputs of motor 2 as courtesy light, be
careful NOT to connect the motor capacitor.
Configures the system for 2 motors.
E
Enables STEP-BY-STEP WITH STOP LOGIC
Operation:
Start
Next start
Next start
E
Next start
If automatic closing has been activated (menu C1) and the opening
phase has arrived at end of cycle, when the pause time has
elapsed (menu H9), the control unit automatically closes the gate.
Enables STEP-BY-STEP LOGIC
Operation:
Start
Next start
E
Next start
If automatic closing has been activated (menu C1) and the opening
phase has arrived at end of cycle, when the pause time has
elapsed (menu H9), the control unit automatically closes the gate.
Enables AUTOMATIC/CONDOMINIUM LOGIC
Operation:
Start
E
Subsequent Start commands → are uninfluential if the control unit is
opening the gate or if the commands reset the pause time (if the
gate is in pause). When the pause time has elapsed, the control unit
automatically closes the gate regardless of the C1 menu.
Enables DEAD MAN'S LOGIC
Operation:
Start
opens only if the Start button is held down.
In Dead Man's mode the buttons on the control unit assume the
E
following meanings:
Start (+ button)
Pedestrian (- button)
open
stop
close
open
open
close
open
open
open
close