Distributed Constant Voltage Outputs
70 Volt Operation:
The CMX 300V and 500V must be configured for Bridge Mono mode for 70
Volt operation. Please refer to the above section on Bridge Mono mode for
proper setup configuration.
The CMX 800V can operate in 70 Volt operation in Stereo mode or Bridge
Mono mode.
100 Volt Operation:
The CMX 500V and CMX 800V must be configured for Bridge Mono mode for
100 Volt operation. Please refer to the Bridge Mono mode section for proper
setup configuration.
Channel 1
input
Channel 2
input
not used
Channel 1
signal input
Channel 2
No input!
Can be used to Daisy-chain
additional amplifiers
– Figure 19 –
10
Amplifier #2 input
CMX
Specifications
300V
Stereo Mode (Both Channels Driven)
70 Volt
-
100 Volt
-
Bridge Mono Mode
70 Volt
600 W
100 Volt
-
– Table 2 –
CMX
CMX
500V
800V
-
400 W
-
-
1200 W
2000 W
600 W
2300 W