External Power Supply - "Battery Off - Waeco CoolFreeze CF-32UP Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
CF-32UP.book Seite 45 Donnerstag, 16. Juli 2009 5:21 17
10.2
External power supply – "BATTERY OFF"
Fault
Device does not
function, "POWER"
LED does not light up.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"ERROR" LED flashes).
The status LED
(fig. 4 1, page 4)
flashes.
When operating from
the 12/24 V socket
(cigarette lighter):
The ignition is on,
the device is not
working and the
"POWER" LED is
not lit.
The display shows
an error message
(e.g. "Err1") and the
device does not cool.
The display remains
dark after switching
on the device.
Possible cause
There is no voltage
present in the 12/24 V
socket (cigarette lighter)
in the vehicle.
Plug fuse is defective.
Defective compressor.
Battery voltage is too low. Test the battery and charge it as needed.
The power supply is
too low.
The cigarette lighter
socket is dirty.
This results in a poor
electrical contact.
The fuse of the 12/24 V
plug has blown.
The vehicle fuse has
blown.
The device has switched
off due to an internal fault.
The battery monitor
is checking the
power supply.
Troubleshooting
Suggested remedy
The ignition must be switched on in most
vehicles to supply current to the cigarette
lighter.
Replace the plug fuse, see "Replacing the
plug fuse (12/24 V)" on page 42.
This can only be repaired by an
authorised repair centre.
Check the external power supply.
Pull the plug out of the socket and make
the following checks.
If the plug of your cooler becomes very
warm in the cigarette lighter socket, either
the lighter socket must be cleaned or the
plug has not been assembled correctly.
Replace the fuse (8 A) in the 12 V plug,
see "Replacing the plug fuse (12/24 V)"
on page 42.
Replace the vehicle's 12/24 V socket fuse
(usually 15 A). Please refer to your
vehicle's operating manual.
This can only be repaired by an
authorised repair centre.
Wait about three minutes until the test has
been completed.
45
Tabla de contenido

Solución de problemas

loading